• Accuracy: (for each channel) N2, 20 ºC, 101.325 kPa (1 atm):
0,1-100% / FS: 2% of setpoint
• Repeatability: 0,20% of reading
• Response time: (for each channel) 1000 ms
• Power Supply: In Bundle
• Operation Pressure: Max 5 bar
• Working Temperature: 0 – 50 °C
• Mass Flow Rates: (for each channel) 0 – 15000 mL/min (standard)
• Total Mixture Flow Rate: Up to 45 L/min
• Gases: N2, O2, CO2, CH4, Air, He, H2. (additional gases supported on request)
• Compatibility: Profibus, Modbus, Matlab Simulink
• Communication: RS485 with open proprietary protocol.
• Fittings: It depends from the applications.
• Inlet Gas Channel: 3 Inputs
• Outlet Gas Channel: 1 Output of mixed gases
• User Interface: Resistive Touch Display.
• Certifications: CE, Made in Italy